Complete set of automatic equipment for cage raising of laying hens / broilers
Hotline: 0532-88133263 Chinese version | ENGLISH

Environment automatic control system

  •  Environment automatic control system
 Environment automatic control system

Environment automatic control system

According to the climate conditions in different regions, equipment type, chicken type, farm construction and other factors, the configuration scheme is obtained through system calculation.
1. Environment controller

In closed cage, the environment in the chicken house can be controlled automatically by the imported environmental controller. In case of high temperature, low temperature and power failure, it can automatically alarm and automatically adjust according to the temperature and humidity set in the chicken house, so as to realize the automatic exchange of longitudinal and transverse ventilation in the chicken house, so as to ensure that chickens in different regions and seasons can grow in the appropriate environment and greatly improve the economic benefits.


A variety of environmental control instruments are available


2. Fan


Technical parameters of axial flow fan:

model Fan diameter mm Air volume m 3 / h Speed rpm Frequency Hz Voltage V Current a Power kw Dimension mm Weight kg
DM1380(50in) one thousand two hundred and seventy forty-three thousand one hundred and seventy one thousand four hundred and forty fifty three hundred and eighty two point eight one point one 1380*1380*450 eighty-nine
DM1000(36in) nine hundred and ten twenty thousand and eight hundred one thousand four hundred and forty fifty three hundred and eighty one point two five zero point four 1000*1000*450 fifty-four
Technical parameters of fan with air duct:

model Fan diameter mm Air volume m 3 / h Speed rpm Frequency Hz Voltage V Current a Power kw Dimension mm Weight kg
DM1380(50in) one thousand two hundred and seventy forty-three thousand five hundred and thirty one thousand four hundred and forty fifty three hundred and eighty two point eight one point one 1380*1380*1180 one hundred and sixteen
DM1000(36in) nine hundred and ten twenty-seven thousand one hundred and sixty one thousand four hundred and forty fifty three hundred and eighty one point two five zero point four 1000*1000*1080 sixty-four

3. Air inlet window

The unique structure of the upper edge of the door is more tightly closed with the upper edge of the window;
There are wind baffles on both sides of the interior of the window, which can effectively prevent the cold wind from blowing down, and let the fresh air rush to the center of the poultry house, so that the air exchange effect is more ideal;
The most reasonable position of the return spring is selected. The unique design not only solves the problem of severe bending deformation of the window door under long-term force, but also places the reinforcing rib inside the window to make the window more solid and not easy to deform;
The window edge can be properly equipped with a guide device;
● direct fresh air to the top of the ceiling;
● allow the fresh air to accelerate to the center of the wider house, provide enough fresh air for the animals in the wide house, and minimize the emergency of animals;


4. Wet curtain cooling system
In the late stage, the paper is made of special corrugated and long-lasting paper, which is characterized by the use of special wet fiber and long service life.
characteristic
Moisture absorption: the surface of wet curtain is treated by special formula and process, which can keep good hygroscopicity and prevent water droplets from forming on the surface.
Quick drying: when the water stops flowing on the wet curtain surface, the protective coating on the surface will dry quickly, so as to prevent the survival of organic microorganisms parasitic on the surface, thus inhibiting the growth of organic matters such as algae on the surface.
No micropores on the surface: it can prevent the water and minerals from staying in the deep layer and take off from the surface when drying.

5. Deflector
In the cold season, it is closed to keep warm, and in the season of longitudinal ventilation, it is used to adjust the size of air inlet and the direction of fresh air flow.
Eliminate the large area ventilation dead zone near the two sides of the wall during longitudinal ventilation;
Control the air flow direction, spin in the air flow, and better mix the air;
The heating cost is about 15% lower than that of ordinary rolling shutter;
It is easy to adjust the opening according to the instruction from the environmental controller.